Microprocessor Based Indicator

AccuCon Series Panel Meter for

Strain Gauge/Load Cell or Voltage/Current

  • Strong Anodized NEMA4X-IP56 aluminum 1/8 DIN case
  • 4 1/2 DIGIT LED display
  • Provides excitation to transducers or sensors
  • Accept DC mV/V, V, mA signal
  • Proportional analog output V or mA
  • Easy to program using 4 buttons
  • Front panel shunt calibration
  • User programmable High & Low set point
  • Standard No-Output or Relay Output
  • Prevent Accidental or Unauthorized Change of Data
  • Power Supply: 85-245V AC 50-60Hz
  • Optional 8-Step Output, RS232, or BCD Output Available
strain gauge indicator - AccuCon

Applications

Strain Gauge, Load Cells, Pressure Transducers, Torque Transducers, Distance Measurement, Temperature Measurement, Flow Meters, Potentiometers, etc.

AccuCon4100 for Strain Gauge Transducers

  • Input Type: 1 to 3mV/V

  • Sample Rate: 15 samples per second
  • Accuracy: +/-0.02% of full scale
  • Analog Output: 
            0 to 5V or 0 to 10V or 
            0 to 20mA or 4 to 20mA
  • Control Output: High/Low Relays
  • Sensor Excitation: 10V DC
  • Data Hold: Freeze Display When Active
  • Peak Hold: Display Peak Reading When Active
  • Data Protection: Prevent Accidental or Unauthorized Change of Data
  • Power Supply: 85V-245V AC (50-60Hz)


AccuCon4150 for Strain Gauge Transducers

  • Input Type: 1 to 3mV/V

  • Sample Rate: 15 samples per second
  • Accuracy: +/-0.02% of full scale
  • Analog Output: N/A
  • Control Output: N/A
  • Sensor Excitation: 10V DC
  • Data Hold: N/A
  • Peak Hold: Display Peak Reading When Active
  • Data Protection: Prevent Accidental or Unauthorized Change of Data
  • Power Supply: 85V-245V AC (50-60Hz)

AccuCon4200 for Voltage/Current Transducers

  • Input Type: 
            0 to 5V or 0 to 10V or 
            0 to 20mA or 4 to 20mA

  • Sample Rate: 15 samples per second
  • Accuracy: +/-0.02% of full scale
  • Analog Output: 
            0 to 5V or 0 to 10V or 
            0 to 20mA or 4 to 20mA
  • Control Output: High/Low Relays
  • Sensor Excitation: 10V DC, 24V DC
  • Data Hold: Freeze Display When Active
  • Peak Hold: Display Peak Reading When Active
  • Data Protection: Prevent Accidental or Unauthorized Change of Data
  • Power Supply: 85V-245V AC (50-60Hz)

AccuCon4250 for Voltage/Current Transducers

  • Input Type: 
            0 to 5V or 0 to 10V or 
            0 to 20mA or 4 to 20mA

  • Sample Rate: 15 samples per second
  • Accuracy: +/-0.02% of full scale
  • Analog Output: N/A
  • Control Output: N/A
  • Sensor Excitation: 10V DC, 24V DC
  • Data Hold: N/A
  • Peak Hold: Display Peak Reading When Active
  • Data Protection: Prevent Accidental or Unauthorized Change of Data
  • Power Supply: 85V-245V AC (50-60Hz)